3M ANZ Electrical Catalogue 2015 Low Res - page 46

41
3M
Medium Voltage Cold Shrink
Cable Terminations & Joints up to 33 kV
Since the conception of 3M Cold Shrink more than 30 years ago, 3M Cold Shrink technology has been found to be a safer, more reliable and easier
to install solution for medium and high voltage jointing and terminating versus conventional heat shrink alternatives. It is a preferred solution for power
utilities, private power network operators and electrical specifiers globally.
Medium and High Voltage Cable Accessories
After many years of developing our 3M cold shrink product range, with
our customers’ needs in mind, we are proud to offer contractors a wide
range of time and money saving joints and terminations to fit almost any
application.
Why move to 3M Cold Shrink?
• Fast, straightforward installation
• No flame required
• No special site permits needed
• No cooling time needed before energising
• Easier to use in enclosed areas
• Constant radial pressure for optimised environmental
performance
• Less chance of damaging XLPE cable material
• Extensive quality and factory testing programmes
3M cold shrink products
installed and trusted worldwide
for over
40 years
3M
Cold Shrink Cable Termination Products
Premium 3M
Cold Shrink Terminations
Fully Integrated: Quick Term III (QT-III)
This fully integrated premium cable termination offers the greatest simplicity
and flexibility in our range. Our premium QT-III termination covers a wide
range of cable sizes and types as well as accommodating voltages up to
69 kV. Shorter installation length enables this product to fit into a wide range
of boxes, and fewer installation steps reduce the risk of error.
Standard 3M
Cold Shrink Terminations
Part Integrated: Quick Term II (QT-II)
Our part integrated Cold Shrink termination offers a viable cost-based
alternative to heat shrink cable terminating technology. Additional process
steps to our QT-III premium range mean that comparative time savings are
less but the benefits of not having to use heat or extra tooling still apply.
This range covers many of the most common cable configurations and size
ranges.
QT-III
QT-II
Moisture Blocking Mastic
Integrated into
termination
Applied separately
Outer Insulator
Very good track
resistance
Good track resistance
Stress Control Tube
Integrated into
termination
Integrated into
termination
Silicone Grease - Stress Relief
No - Integrated
mastic is sufficient
Yes - Applied
separately
Stress Control Mastic
Integrated into
termination
No - Requires
silicone grease
The simple application of a 3M
Cold Shrink Cable Termination
Prepare the cable as normal and clean with
3M
Cable Wipes
Place the 3M
Cold Shrink Termination Body
over the cable end and position at the correct
point on the cable
1
2
Begin to remove the inner core, allowing the
termination to shrink down onto the cable
Once the inner core has been fully removed, the
termination installation is complete!
3
4