Medium Voltage Cold Shrink Cable Termination Kits
(Australia)
Final determining factors are cable jacket and insulation diameters.
Voltage Description
No.
Cores
Cable Size
mm
2
Cable
Insulation
Range
mm
BIL
kV
NON-ARMOURED CABLE
ARMOURED CABLE
Jacket
Diameter
Range
mm
3M Kit
3M Order Code
Jacket
Diameter
Range
mm
3M Kit
3M Order Code
11 kV
Indoor
1
16 - 25 11.2 - 16.5 95 Max. 23
92-EB 60-1-AU
AE010591962 14 - 24
92-EB 60-1-AR-AU
AE010592135
35
14.2 - 22.1 95 Max. 28
92-EB 61-1-AU
AE010591970 23 - 41
92-EB 61-1-AR-AU
AE010592143
50 - 150 15.9 - 30.0 95 18 - 37
92-EB 62-1-AU
AE010591988 23 - 41
92-EB 62-1-AR-AU
AE010592150
185 - 500 22.6 - 41.4 95 25 - 50
92-EB 63-1-AU
AE010591996 33 - 56
92-EB 63-1-AR-AU
AE010592168
300 - 630 27.3 - 49.3 95 29 - 61
92-EB 64-1-AU
AE010592002 42 - 79
92-EB 64-1-AR-AU
AE010592176
500 - 1000 31.5 - 61.5 95 34 - 74
92-EB 65-1-AU
AE010592010 42 - 79
92-EB 65-1-AR-AU
AE010592184
Outdoor
1
50 - 150 16.0 - 28.5 125 23 - 35
93-EB 62-1-AU
AE010592028 23 - 41
93-EB 62-1-AR-AU
AE010592192
150 - 300 21.3 - 35.0 125 30 - 44
93-EB 63-1-AU
AE010592036 33 - 56
93-EB 63-1-AR-AU
AE010592200
300 - 630 27.0 - 45.7 125 35 - 52
93-EB 64-1-AU
AE010592044 35 - 56
93-EB 64-1-AR-AU
AE010592218
500 - 1000 33.0 - 53.3 125 41 - 65
93-EB 65-1-AU
AE010592051 42 - 79
93-EB 65-1-AR-AU
AE010592226
15 kV
Indoor
1
25
14.2 - 22.1 95 Max. 28
92-EB 61-1-AU
AE010591970 23 - 41
92-EB 61-1-AR-AU
AE010592143
35 - 120 15.9 - 30.0 95 18 - 37
92-EB 62-1-AU
AE010591988 23 - 41
92-EB 62-1-AR-AU
AE010592150
150 - 400 22.6 - 41.4 95 25 - 50
92-EB 63-1-AU
AE010591996 33 - 56
92-EB 63-1-AR-AU
AE010592168
240 - 500 27.3 - 49.3 95 29 - 61
92-EB 64-1-AU
AE010592002 42 - 79
92-EB 64-1-AR-AU
AE010592176
400 - 800 31.5 - 61.5 95 34 - 74
92-EB 65-1-AU
AE010592010 42 - 79
92-EB 65-1-AR-AU
AE010592184
Outdoor
1
35 - 120 16.0 - 28.5 125 23 - 35
93-EB 62-1-AU
AE010592028 23 - 41
93-EB 62-1-AR-AU
AE010592192
120 - 240 21.3 - 35.0 125 30 - 44
93-EB 63-1-AU
AE010592036 33 - 56
93-EB 63-1-AR-AU
AE010592200
240 - 500 27.0 - 45.7 125 35 - 52
93-EB 64-1-AU
AE010592044 35 - 56
93-EB 64-1-AR-AU
AE010592218
400 - 1000 33.0 - 53.3 125 41 - 65
93-EB 65-1-AU
AE010592051 42 - 79
93-EB 65-1-AR-AU
AE010592226
22 kV
Indoor
1
25 - 95 16.0 - 28.5 125 23 - 35
93-EB 62-1-AU
AE010592028 23 - 41
93-EB 62-1-AR-AU
AE010592192
70 - 240 21.3 - 35.0 125 30 - 44
93-EB 63-1-AU
AE010592036 33 - 56
93-EB 63-1-AR-AU
AE010592200
185 - 500 27.0 - 45.7 125 35 - 52
93-EB 64-1-AU
AE010592044 35 - 56
93-EB 64-1-AR-AU
AE010592218
400 - 1000 33.0 - 53.3 125 41 - 65
93-EB 65-1-AU
AE010592051 42 - 79
93-EB 65-1-AR-AU
AE010592226
Outdoor
1
25 - 95 16.2 - 28.5 170 23 - 35
94-EB 62-1-AU
AE010592069 23 - 41
94-EB 62-1-AR-AU
AE010592234
70 - 240 21.3 - 35.0 170 30 - 44
94-EB 63-1-AU
AE010592077 33 - 56
94-EB 63-1-AR-AU
AE010592242
185 - 500 27.4 - 45.7 170 35 - 52
94-EB 64-1-AU
AE010592085 35 - 56
94-EB 64-1-AR-AU
AE010592259
400 - 1000 33.3 - 53.3 170 41 - 65
94-EB 65-1-AU
AE010592093 42 - 79
94-EB 65-1-AR-AU
AE010592267
33 kV
Indoor
1
25 - 50 16.2 - 28.5 170 23 - 35
94-EB 62-1-AU
AE010592069 23 - 41
94-EB 62-1-AR-AU
AE010592234
50 - 150 21.3 - 35.0 170 30 - 44
94-EB 63-1-AU
AE010592077 33 - 56
94-EB 63-1-AR-AU
AE010592242
120 - 300 27.4 - 45.7 170 35 - 52
94-EB 64-1-AU
AE010592085 35 - 56
94-EB 64-1-AR-AU
AE010592259
240 - 500 33.3 - 53.3 170 41 - 65
94-EB 65-1-AU
AE010592093 42 - 79
94-EB 65-1-AR-AU
AE010592267
Outdoor
1
50 - 150 21.3 - 35.0 170 30 - 44
94-EB 62-2-AU
AE010592101 33 - 56
94-EB 62-2-AR-AU
AE010592275
120 - 240 27.0 - 45.7 170 34 - 52
94-EB 63-2-AU
AE010592119 34 - 56
94-EB 63-2-AR-AU
AE010592283
240 - 630 33.3 - 53.3 170 41 - 65
94-EB 64-2-AU
AE010592127 42 - 79
94-EB 64-2-AR-AU
AE010592291
Cold Shrink QT-II Termination Kits for Single Core Cable (AU)
3M Cold Shrink QT-II Termination Kits
Single Core Cable - 11kV, 15 kV, 22 kV, 33 kV
Cable:
Polymeric Insulation, Copper Wire Screened, Non-Armoured or Armoured
Contents:
Each kit will make three single core terminations. Lugs not included.