46
Medium Voltage Cold Shrink Cable Termination Kits
(Australia)
Voltage Description
No.
Cores
Cable Size
mm
2
Cable
Insulation
Range
mm
BIL
kV
NON-ARMOURED CABLE
ARMOURED CABLE
Jacket
Diameter
Range
mm
3M Kit
3M Order Code
Jacket
Diameter
Range
mm
3M Kit
3M Order Code
3.3 kV
Indoor
1
25 - 70 11.2 - 16.5 95 Max. 23
92-EB 60-1-AU
AE010591962 14 - 24
92-EB 60-1-AR-AU
AE010592135
70 - 185 14.2 - 22.1 95 Max. 28
92-EB 61-1-AU
AE010591970 23 - 41
92-EB 61-1-AR-AU
AE010592143
95 - 300 15.9 - 30.0 95 18 - 37
92-EB 62-1-AU
AE010591988 23 - 41
92-EB 62-1-AR-AU
AE010592150
240 - 500 22.6 - 41.4 95 25 - 50
92-EB 63-1-AU
AE010591996 33 - 56
92-EB 63-1-AR-AU
AE010592168
400 - 630 27.3 - 49.3 95 29 - 61
92-EB 64-1-AU
AE010592002 42 - 79
92-EB 64-1-AR-AU
AE010592176
500 - 1000 31.5 - 61.5 95 34 - 74
92-EB 65-1-AU
AE010592010 42 - 79
92-EB 65-1-AR-AU
AE010592184
Outdoor
1
95 - 300 16.0 - 28.5 125 23 - 35
93-EB 62-1-AU
AE010592028 23 - 41
93-EB 62-1-AR-AU
AE010592192
240 - 500 21.3 - 35.0 125 30 - 44
93-EB 63-1-AU
AE010592036 33 - 56
93-EB 63-1-AR-AU
AE010592200
400 - 630 27.0 - 45.7 125 35 - 52
93-EB 64-1-AU
AE010592044 35 - 56
93-EB 64-1-AR-AU
AE010592218
500 - 1000 33.0 - 53.3 125 41 - 65
93-EB 65-1-AU
AE010592051 42 - 79
93-EB 65-1-AR-AU
AE010592226
6.6 kV
Indoor
1
25 - 50 11.2 - 16.5 95 Max. 23
92-EB 60-1-AU
AE010591962 14 - 24
92-EB 60-1-AR-AU
AE010592135
70 - 150 14.2 - 22.1 95 Max. 28
92-EB 61-1-AU
AE010591970 23 - 41
92-EB 61-1-AR-AU
AE010592143
95 - 300 15.9 - 30.0 95 18 - 37
92-EB 62-1-AU
AE010591988 23 - 41
92-EB 62-1-AR-AU
AE010592150
240 - 500 22.6 - 41.4 95 25 - 50
92-EB 63-1-AU
AE010591996 33 - 56
92-EB 63-1-AR-AU
AE010592168
400 - 630 27.3 - 49.3 95 29 - 61
92-EB 64-1-AU
AE010592002 42 - 79
92-EB 64-1-AR-AU
AE010592176
500 - 1000 31.5 - 61.5 95 34 - 74
92-EB 65-1-AU
AE010592010 42 - 79
92-EB 65-1-AR-AU
AE010592184
Outdoor
1
95 - 240 16.0 - 28.5 125 23 - 35
93-EB 62-1-AU
AE010592028 23 - 41
93-EB 62-1-AR-AU
AE010592192
240 - 400 21.3 - 35.0 125 30 - 44
93-EB 63-1-AU
AE010592036 33 - 56
93-EB 63-1-AR-AU
AE010592200
400 - 630 27.0 - 45.7 125 35 - 52
93-EB 64-1-AU
AE010592044 35 - 56
93-EB 64-1-AR-AU
AE010592218
500 - 1000 33.0 - 53.3 125 41 - 65
93-EB 65-1-AU
AE010592051 42 - 79
93-EB 65-1-AR-AU
AE010592226
Final determining factors are cable jacket and insulation diameters.
Cold Shrink QT-II Termination Kits for Single Core Cable (AU)
3M Cold Shrink QT-II terminations provide easy installation for a broad spectrum of indoor and outdoor
applications. The Cold Shrink QT-II is based on specially formulated, track-resistant silicone rubber insulators
with built-in Hi-K stress relief. Once applied this provides a void-free, flexible seal without the need for special
tools or torches. Kits are designed for use with crimp lugs. For use with mechanical lugs please contact 3M.
3M Cold Shrink QT-III Termination Kits
Three Core Cable - 15 kV, 22 kV, 33 kV
Cable:
Polymeric Insulation, Copper Wire Screened, Non-Armoured or Armoured
Contents:
Each kit will make one three core termination. Lugs not included.
Termination kits for single and three core cable are specifically designed and optimised for Australian
conditions, and meet or exceed the requirements of IEC 60502-4 and IEEE Standard 48.